Power450 KW
Country of OriginMade in India

Minimum order quantity: 1 Piece

Model Name/Number ABB PSTX Soft Starter
Motor Current 30-1250 A
Motor Voltage 208-600 V AC
Model Series PSTX30 -1250 A
Rated Operational Current Range 30A to 1250A
Rated Operational Voltage 208...600 V,208...690V +10% / -15%,50/60Hz +/-10%
Rated Insulation Voltage 690V
Rated Control Supply Voltage 100 to 250 V +10% / -15%,50/60Hz +/-10%
Rated Control Circuit Voltage Internal or external 24 V DC
Number Of Starts Per Hour 10 for PSTX30 ... PSTX370; 6 for PSTX470 ... PSTX1250
Built-In Bypass Available
Fieldbus Built-in Modbus RTU ;Connection for Anybus ;Connection for ABB FieldBusPlug (with adapter)
Cooling System Fan cooled (thermostat controlled)
Display LCD type Display,graphical
Keypad Detachable keypad,2 selection,4 navigation,1 start,1 stop key,info key & remote/local key
Number Of Programmable Signal Relays 3 Relay output (each can be programmed to None,Run,Top of ramp)
Ip Degree Of Protection Supply and control circuit IP20
Ambient Temperature During operation -25...+60 deg C,(-13...+140 F) 2)
Brand ABB
Application Crushers, Pumps, Fans/Blowers, Compressors, Saw

The advance Range:

Rated Motor Current-30-1250A Inside Delta 2160A
Main motor Voltage -208-600VAC
Other Details

Environmental LimitsAmbient Temperature During operation -25 to +60 Degree C, (-13 to +140 F) 2), During storage -40 to +70 Degree C, (-40 to +158 F)

Start and Stop Functions
  • Soft start with a voltage ramp
  • Soft stop with the voltage ramp
  • Soft start with torque control
  • Soft stop with torque control
  • Kickstart
  • Full voltage start
  • Sequence start 3 different sets of settings
  • Current limit
  • Dual current limit
  • Current limit ramp
  • Torque limit
  • Pre-start function (Motor heating or Stand still brake)
  • Jog with slow speed, forward and reverse (3-speed levels)
  • Start reverse
  • Dynamic brake

Protections
  • Electronic overload protection, EOL
  • Dual overload (separate overload for start and run)
  • PTC connection
  • PT-100 connection
  • Locked rotor protection
  • Current underload protection
  • Current imbalance protection
  • Power factor underload protection
  • Under voltage protection
  • Overvoltage protection
  • Voltage imbalance protection
  • Earth fault protection/ground fault protection
  • Phase reversal protection
  • 24 V output protection
  • Frequency range protection
  • Bypass open protection
  • User-defined protection
  • Too long current limit protection
  • HMI failure protection
  • Fieldbus failure protection
  • Extension IO failure protection
  • Max number of starts/hour
X